FILLING
The following filling procedure is to be used when fryer is first filled with cooking oil
and when cooking oil is changed.
1. Turn off Power Switch.
2. Clean Fryer per daily cleaning procedure - see pages 18-19.
3. Lubricate Collector Gasket with cooking oil before placing on collector.
4. Check Collector and Drain Valve - Make sure collector with gasket is sealed
and drain valve is closed (handle pointing towards top rear of fryer–see
Figure 1).
5. Add Cooking Oil - Add enough cooking oil to
reach a level between the Maximum and
Minimum oil level lines (see Figure 2).
CAUTION: Cooking oil may be hot enough to
burn you. Be careful when moving containers
of liquid cooking oil.
DANGER: Fire or heater damage may occur when
heaters are turned ON unless they are fully
covered with cooking oil.
Heater Coils
Gasket
Drain Valve
Closed
Lifting Loop
Cone
Collector
Heater Coils
FIGURE 2
Shown with long
collector.