PROGRAMMING
8000 Series Computer Controller
For Collectramatic
®
Open and
Pressure Fryers
Models OF49C, OF59C,
PF46C, PF56C
STEP 3
STEP 4
STEP 5
STEP 6
STEP 7
STEP 8
STEP 9
STEP 10
STEP 11
STEP 12
STEP 13
Note: At any time during programming time settings can be set to :00 indicating
from that point on, the fryer will cook at the last setting entered until the end of the
cycle.
When the computer
displays
Current temperature setting
sample
Current time
setting sample
Current vent
setting sample
Press button/Action
Heat setpoints H1
or
Time setpoint t1
or
or
Note
Indicates Programming
mode. Press ENTER to
proceed.
Press channel button #5
for selecting process #5
Press ENTER to proceed.
H1 displays momentarily.
Use arrow buttons to
modify. Hold either button
for fast scrolling. Will
display in F or C.
250˚F minimum,
360˚F maximum.
Press ENTER to proceed.
t1 displays momentarily.
Use arrow buttons to
modify. Hold either button
for fast scrolling. Display
shows MM:SS
(minutes:seconds).
:00 minimum
99:55 maximum.
Press ENTER to proceed.
Use arrow button to
toggle between Open (O)
and Pressure (P).
Press ENTER to exit.
ENTER
ENTER
ENTER
ENTER
ENTER
5
0
0
0